LANDSON / PETROCHEMICAL

PETROCHEMICAL PRODUCT RECOVERY

PETROCHEMICAL PRODUCT RECOVERY

PETROCHEMICAL PRODUCT RECOVERY

Recovery from highly corrosive acetic-acid streams with cross-flow SiC filtration instead of metallic membranes.

Recovery from highly corrosive acetic-acid streams with cross-flow SiC filtration instead of metallic membranes.

Recovery from highly corrosive acetic-acid streams with cross-flow SiC filtration instead of metallic membranes.

Treatment challenge

Treatment challenge

Treatment challenge

Recovery of high-value particles from aggressive petrochemical streams containing 87% acetic acid at temperatures up to 90°C required a durable alternative to metallic membranes.

Recovery of high-value particles from aggressive petrochemical streams containing 87% acetic acid at temperatures up to 90°C required a durable alternative to metallic membranes.

Landson SiC membrane solution

Landson SiC membrane solution

Landson SiC membrane solution

Landson SiC operates in cross-flow mode and permits direct flushing with hot acetic acid. Six SiC elements replace a comparison system using 243 Hastelloy membrane elements.

Landson SiC operates in cross-flow mode and permits direct flushing with hot acetic acid. Six SiC elements replace a comparison system using 243 Hastelloy membrane elements.

Reported performance and operating conditions

Reported performance and operating conditions

Reported performance and operating conditions

Filtration flux 750 LMH at 0.5 bar; particle recovery >99%; 46.8 m² SiC filtration area; operating temperature up to 90°C. Reported metallic comparison: 400 LMH at 1 bar and 48.6 m².

Filtration flux 750 LMH at 0.5 bar; particle recovery >99%; 46.8 m² SiC filtration area; operating temperature up to 90°C. Reported metallic comparison: 400 LMH at 1 bar and 48.6 m².

Technical configuration

Technical configuration

Technical configuration

6 SiC elements Ø146 × 865 mm, 0.2 µm average pore size · Cross-flow · 87% acetic acid · 90°C maximum.

6 SiC elements Ø146 × 865 mm, 0.2 µm average pore size · Cross-flow · 87% acetic acid · 90°C maximum.

Project status and significance

Project status and significance

Project status and significance

The reported system uses a 300 L filtration vessel versus 10,000 L for the compared metallic system. The document reports no SiC element replacements during the first five years of operation.

The reported system uses a 300 L filtration vessel versus 10,000 L for the compared metallic system. The document reports no SiC element replacements during the first five years of operation.

Interpreting the results

Interpreting the results

Interpreting the results

Figures reflect the project information in the Landson case-study materials and are application-specific.

Figures reflect the project information in the Landson case-study materials and are application-specific.

>99% Particle recovery · 750 LMH Flux at 0.5 bar

>99% Particle recovery · 750 LMH Flux at 0.5 bar